Instrumentation Lab Gap Matrix: Unterschied zwischen den Versionen
Zur Navigation springen
Zur Suche springen
(→Aerodynamics and Performance: Grundkonzept Tabelle) |
|||
Zeile 10: | Zeile 10: | ||
== Aerodynamics and Performance == | == Aerodynamics and Performance == | ||
issued 22 February 2017 | issued 22 February 2017 | ||
− | |||
<table class="wikitable"> | <table class="wikitable"> | ||
<tr> | <tr> | ||
+ | <!-- | ||
+ | |||
+ | Block 1 headline | ||
+ | --> | ||
<th width="15%" style="text-align: left;"><span class="mw-customtoggle-AA" style="color: #0645AD;">Measurand/Measurement</span></th> | <th width="15%" style="text-align: left;"><span class="mw-customtoggle-AA" style="color: #0645AD;">Measurand/Measurement</span></th> | ||
<th width="10%">Externals and shafts</th> | <th width="10%">Externals and shafts</th> | ||
Zeile 27: | Zeile 30: | ||
<tr id="mw-customcollapsible-AA" class="mw-collapsible mw-collapsed"><td>Temperature (MKS)</td> <td>-40 to 300°C</td> <td>-40 to 300°C</td> <td>300 to 700°C+</td> <td>700°C-2400°C</td> <td>1000°C-1800°C</td> <td>700°C-1000°C</td> <td>700°C+</td></tr> | <tr id="mw-customcollapsible-AA" class="mw-collapsible mw-collapsed"><td>Temperature (MKS)</td> <td>-40 to 300°C</td> <td>-40 to 300°C</td> <td>300 to 700°C+</td> <td>700°C-2400°C</td> <td>1000°C-1800°C</td> <td>700°C-1000°C</td> <td>700°C+</td></tr> | ||
<tr id="mw-customcollapsible-AA" class="mw-collapsible mw-collapsed"><td>Temperature (Eng)</td> <td>-40 to 570F</td> <td>-40 to 570F</td> <td>570 to 1300F+</td> <td>1300F-4300F</td> <td>1800F-3300F</td> <td>1300F-1800F</td> <td>1300F</td></tr> | <tr id="mw-customcollapsible-AA" class="mw-collapsible mw-collapsed"><td>Temperature (Eng)</td> <td>-40 to 570F</td> <td>-40 to 570F</td> <td>570 to 1300F+</td> <td>1300F-4300F</td> <td>1800F-3300F</td> <td>1300F-1800F</td> <td>1300F</td></tr> | ||
+ | <!-- | ||
+ | --> | ||
+ | <tr><th colspan="8" style="text-align: left;">TRL assessments = Red 1-4, Yellow 5-6, Green 7-9</th></tr> | ||
+ | <!-- | ||
− | + | 1. Airflow Measurements | |
− | + | --> | |
− | |||
− | |||
− | |||
<tr> | <tr> | ||
<th style="text-align: left;"><span class="mw-customtoggle-BB" style="color: #0645AD;">1. Airflow Measurements</span></th> | <th style="text-align: left;"><span class="mw-customtoggle-BB" style="color: #0645AD;">1. Airflow Measurements</span></th> | ||
<td></td><td style="background:green"></td><td></td><td></td><td></td><td></td><td></td></tr> | <td></td><td style="background:green"></td><td></td><td></td><td></td><td></td><td></td></tr> | ||
− | |||
<tr id="mw-customcollapsible-BB" class="mw-collapsible mw-collapsed"><td>Intake/core mass flow (Total/static P)</td> | <tr id="mw-customcollapsible-BB" class="mw-collapsible mw-collapsed"><td>Intake/core mass flow (Total/static P)</td> | ||
<td></td><td style="background:green"></td><td></td><td></td><td></td><td></td><td></td></tr> | <td></td><td style="background:green"></td><td></td><td></td><td></td><td></td><td></td></tr> | ||
Zeile 50: | Zeile 53: | ||
<tr id="mw-customcollapsible-BB" class="mw-collapsible mw-collapsed"><td>other</td> | <tr id="mw-customcollapsible-BB" class="mw-collapsible mw-collapsed"><td>other</td> | ||
<td></td><td></td><td></td><td></td><td></td><td></td><td></td></tr> | <td></td><td></td><td></td><td></td><td></td><td></td><td></td></tr> | ||
+ | <tr id="mw-customcollapsible-BB" class="mw-collapsible mw-collapsed"><th colspan="8"></th></tr> | ||
+ | <!-- | ||
− | + | 2. Gas Path Measurements | |
− | <tr> | + | --> |
− | <th style="text-align: left;"><span class="mw-customtoggle-CC" style="color: #0645AD;">2. Gas Path Measurements</span></th> | + | <tr><th style="text-align: left;"><span class="mw-customtoggle-CC" style="color: #0645AD;">2. Gas Path Measurements</span></th> |
<td></td><td></td><td></td><td></td><td></td><td></td><td></td></tr> | <td></td><td></td><td></td><td></td><td></td><td></td><td></td></tr> | ||
+ | <!-- | ||
+ | --> | ||
<tr id="mw-customcollapsible-CC" class="mw-collapsible mw-collapsed"><th style="text-align: left" colspan="8">2a. Gas Path: Dynamic Pressure Measurements</th></tr> | <tr id="mw-customcollapsible-CC" class="mw-collapsible mw-collapsed"><th style="text-align: left" colspan="8">2a. Gas Path: Dynamic Pressure Measurements</th></tr> | ||
− | |||
<tr id="mw-customcollapsible-CC" class="mw-collapsible mw-collapsed"><td>Piezoelectric</td> | <tr id="mw-customcollapsible-CC" class="mw-collapsible mw-collapsed"><td>Piezoelectric</td> | ||
<td></td><td></td><td></td><td></td><td></td><td></td><td></td></tr> | <td></td><td></td><td></td><td></td><td></td><td></td><td></td></tr> | ||
Zeile 76: | Zeile 82: | ||
<tr id="mw-customcollapsible-CC" class="mw-collapsible mw-collapsed"><td>other</td> | <tr id="mw-customcollapsible-CC" class="mw-collapsible mw-collapsed"><td>other</td> | ||
<td></td><td></td><td></td><td></td><td></td><td></td><td></td></tr> | <td></td><td></td><td></td><td></td><td></td><td></td><td></td></tr> | ||
+ | <!-- | ||
+ | --> | ||
<tr id="mw-customcollapsible-CC" class="mw-collapsible mw-collapsed"><th style="text-align: left" colspan="8">2b. Gas Path: Temperature Measurements</th></tr> | <tr id="mw-customcollapsible-CC" class="mw-collapsible mw-collapsed"><th style="text-align: left" colspan="8">2b. Gas Path: Temperature Measurements</th></tr> | ||
− | |||
<tr id="mw-customcollapsible-CC" class="mw-collapsible mw-collapsed"><td>Rakes, Including noble metals</td> | <tr id="mw-customcollapsible-CC" class="mw-collapsible mw-collapsed"><td>Rakes, Including noble metals</td> | ||
<td></td><td></td><td></td><td></td><td></td><td></td><td></td></tr> | <td></td><td></td><td></td><td></td><td></td><td></td><td></td></tr> | ||
Zeile 103: | Zeile 110: | ||
<tr id="mw-customcollapsible-CC" class="mw-collapsible mw-collapsed"><td>other</td> | <tr id="mw-customcollapsible-CC" class="mw-collapsible mw-collapsed"><td>other</td> | ||
<td></td><td></td><td></td><td></td><td></td><td></td><td></td></tr> | <td></td><td></td><td></td><td></td><td></td><td></td><td></td></tr> | ||
+ | <!-- | ||
+ | --> | ||
<tr id="mw-customcollapsible-CC" class="mw-collapsible mw-collapsed"><th style="text-align: left" colspan="8">2c. Gas Path: Pressure Measurements</th></tr> | <tr id="mw-customcollapsible-CC" class="mw-collapsible mw-collapsed"><th style="text-align: left" colspan="8">2c. Gas Path: Pressure Measurements</th></tr> | ||
− | |||
<tr id="mw-customcollapsible-CC" class="mw-collapsible mw-collapsed"><td>Rakes, Including noble metals</td> | <tr id="mw-customcollapsible-CC" class="mw-collapsible mw-collapsed"><td>Rakes, Including noble metals</td> | ||
<td></td><td></td><td></td><td></td><td></td><td></td><td></td></tr> | <td></td><td></td><td></td><td></td><td></td><td></td><td></td></tr> | ||
Zeile 112: | Zeile 120: | ||
<tr id="mw-customcollapsible-CC" class="mw-collapsible mw-collapsed"><td>other</td> | <tr id="mw-customcollapsible-CC" class="mw-collapsible mw-collapsed"><td>other</td> | ||
<td></td><td></td><td></td><td></td><td></td><td></td><td></td></tr> | <td></td><td></td><td></td><td></td><td></td><td></td><td></td></tr> | ||
− | |||
− | |||
</table> | </table> | ||
Version vom 28. November 2019, 16:05 Uhr
Inhaltsverzeichnis
Description
In order to highlight the research priorities in terms of Gas Turbine Instrumentation Development, PIWG on the US side and EVI-GTI on the EU side have issued a Lab Gap Matrix. A first EVI-GTI version was released in 2004, then updated in 2009, containing measured quantities on one axis mapped against engine location / working environment on the other axis.
Measurement types were structured as follows and after a voting process among OEM’s, each area was highlighted in green, yellow or red depending on their level of maturity or even availability.
Structure
Aerodynamics and Performance
issued 22 February 2017
Measurand/Measurement | Externals and shafts | Intake, Compressor (Front) and Fan | Compressor (rear) | Combustion system | HP Turbine | LP Turbine | Exhaust |
---|---|---|---|---|---|---|---|
Pressure (MKS) | 1 bar | 1-10 bar | 10-45 bar | <45 bar | 25-45 bar | 1-20 bar | 1 bar |
Pressure (Eng) | 15psi | 15-150psi | 150psi-650psi | 650psi | 370psi-650psi | 15psi-300psi | 15psi |
Temperature (MKS) | -40 to 300°C | -40 to 300°C | 300 to 700°C+ | 700°C-2400°C | 1000°C-1800°C | 700°C-1000°C | 700°C+ |
Temperature (Eng) | -40 to 570F | -40 to 570F | 570 to 1300F+ | 1300F-4300F | 1800F-3300F | 1300F-1800F | 1300F |
TRL assessments = Red 1-4, Yellow 5-6, Green 7-9 | |||||||
1. Airflow Measurements | |||||||
Intake/core mass flow (Total/static P) | |||||||
Offtake flow: orrifice plates/nozzles | |||||||
Intake condensation/water content | |||||||
Sand/ash/particulate | |||||||
Multiphase breather flows | |||||||
other | |||||||
2. Gas Path Measurements | |||||||
2a. Gas Path: Dynamic Pressure Measurements | |||||||
Piezoelectric | |||||||
Piezoresistive | |||||||
Capacitance | |||||||
Semi infinite line - remote | |||||||
Plasma discharge | |||||||
MEMS | |||||||
Fiber optic (FPI, FBG) | |||||||
Traversible dynamic pressure | |||||||
other | |||||||
2b. Gas Path: Temperature Measurements | |||||||
Rakes, Including noble metals | |||||||
Metallic Thermocouples | |||||||
Ceramic thermocouple alloys | |||||||
Fiber optic (FPI/FBG/BBR) | |||||||
Absorption technologies | |||||||
Laser based technologies - planar | |||||||
2 D Mapping Tomography | |||||||
Seeded flowpath technologies | |||||||
Acoustic pyrometry | |||||||
Intermittant choked nozzle | |||||||
Traversing | |||||||
other | |||||||
2c. Gas Path: Pressure Measurements | |||||||
Rakes, Including noble metals | |||||||
Traversible steady pressure | |||||||
other |
Rotating Structures
Stationary Structures
External links
- EVI-GTI and
- EVI-GTI Wiki at https://wiki.evi-gti.eu